HMCN type long bag pulsed dust collector is a new type of dust collector which is improved on the basis of cloth bag dust collector.
HMCN type long bag pulse filter used after it is very important to note, not to say that after use to prevent beside regardless of the subsequent operations, equipment malfunction easily like that, once again run time may be because of improper operation unable to function properly, so after shutdown pulse bag filter need to check the parts, to ensure that all is in order to close the equipment operation all working parts, so as to guarantee the equipment again boot operation can also achieve good dust removal effect.
1. Connect the upper limit alarm signal line of the single needle indicating alarm device with the input of the electric control device.
2. Open the travel switch on the three-way valve normally and connect the contact with the indicator light.Connect the power cord of differential pressure transmitter, alarm device and electric control device.
3. The bag dust remover is operated electronically to clean dust and start the main fan.The beginning of the cloth bag filter dust operation, do not immediately start backblowing equipment, should let dust gradually accumulated in the outer appearance of the filter bag.
4. connect the compressed air, check the compressed air pipeline joints, stop valve, water filter, voltage regulator, oil mist.
5. Start the ash transport motor to check whether it works normally.Pulsed dust collector
6. Measure the dynamic pressure value together with the leather in each air inlet pipe of the gray bucket. If the readings are different, adjust and make it flat with the manual butterfly valve to ensure that the load of each filter chamber is flat.
7. Open the backblow manual butterfly valve to the required direction of backblow air volume.
8. electric control dust cleaning equipment: pulse dust collector.